1204A-MC Digital Signal Distribution With Remote Monitor and Control Interface

Building on the success of the 1204A Digital Distribution amplifier, the 1204A-MC is a flexible distribution platform suitable for various pulse formats enhanced with a full remote monitor and control interface. With the added monitor and control, a remote user can easily monitor status of each of the inputs/outputs of the unit on either RS232 or Ethernet with Telnet, web browser and SNMP interfaces. Optionally the unit can take two separate inputs into an input switch with either fully automatic or manual control.

For added flexibility, individual outputs can be enabled/disabled via remote control so that unused outputs are isolated from the alarm system. Input and output status is immediately evident from front panel indicators of each channel. Also auto/manual selection of the auto switched input is available from the front panel key pad. All outputs are provided on convenient BNC connectors. Outputs provide 5V TTL levels into a 50 ohm load.

 Input Frequencies DC to 30MHz
 Suitable for 1PPS, IRIG DCLS etc.
 12 Channel Output Distribution
 Low Skew and Propagation Delay
 Remote Monitoring of Input/Output Levels
 Remote Selection of Active Outputs
 Dual Input with Auto Switch Option
 Low Cost
 Convenient 1U, 19″ rack mount package

Electrical  
Input Level 10V max
Input Impedance 50 ohm
Input High Level 2V to 5V (50 ohm)
Input Low Level <0.7V (50 ohm)
   
Output High Level 3.5V (minimum)
Output Low Level 0.5V (maximum)
Output Impedance 50 ohm

Frequency Range DC to 30MHz
Connectors BNC
Alarm Output Summary alarm
indicates failure of
any output signal
Non-alarm condition: Relay energized
(fail safe)
Connector: 9 pin D-male
Controls & Indicators  
Each Channel Green/Red LED,
Healthy/Fault
Input Manual/Auto
Red LED(manual)
Keypad Manual/Auto
Channel (A/B)
Ethernet RJ 45, Front Panel
RS232 DB9 (Rear panel)
   
Protocols(Ethernet)  
Telnet  
SNMP  
Web Browser  

Environmental & Physical  
Temperature: 0° to 55° C
Relative Humidity: 0 to 95%, non-condensing
Power Requirements  
AC Input (±15%) 90 - 264 VAC, <10W
DC Input (optional)  
Dimensions (HxWxD): 1U x 19” x 12”