1200-MC Series, Broadband RF, Digital, and Time Code Distribution With Remote Monitor and Control Interface

Building on the success of the 1200 series Broadband Distribution amplifiers, the 1200- MC series provides not only high
performance distribution of frequency and timing references, but enhances this with a full remote monitor and control interface.
With the added monitor and control, allows status monitoring of inputs/outputs on either RS232 or Ethernet with Telnet, web browser and SNMP interfaces. Optionally the unit can take two separate inputs into an input switch with either fully automatic or manual control.

Input and output status is immediately evident from front panel indicators of each channel. Also auto/manual selection of the
auto switched input is available from the front panel key pad.
Low jitter / phase noise insures top quality delivery of input to up to 12 output channels.
High isolation insures minimum impact on any other output in the event of one of the outputs being overloaded. Inputs and outputs are provided on convenient BNC connectors. Output drive provides up to 13dBm or 5V CMOS/TTL into a 50 ohm load (dependent upon model). Individual outputs can be enabled / disabled via remote control so that unused outputs are isolated from the alarm system.

Models:
1203C-MC RF Distribution
1204A-MC Digital Distribution
1205A-MC Time Code Distribution

 Input Frequencies 500kHz to 50MHz
 12 output channels
 Low Jitter / Phase Noise
 High Isolation
 Remote Monitoring of RMS Output Levels (Analog versions)
 Remote Selection of Active Outputs
 Dual Input with Auto Switch Option
 Low Cost
 Convenient 1U, 19″ rack mount package

Electrical  
Outputs (twelve)  
Frequency Range (RF) 500kHz to 50MHz
Frequency Range (Digital) DC to 30MHz
Frequency Range (TC) 100Hz to 1MHz
Level 1V rms (RF)
Level 5V TTL (Digital)
Level 6V pk-pk (TC)
Load Impedance 50 ohms
Connectors BNC

Additive SSB Phase Noise (RF version)  
(1 Hz Bandwidth)
Offset from carrier
 
1 Hz -132 dB
10 Hz -150 dB
100 Hz -160 dB
1,000 Hz -165 dB
10,000 Hz -165 dB

Alarm Output Summary alarm
indicates failure of
any output signal
Non-alarm condition: Relay energized
(fail safe)
Connector: 9 pin D-male
Controls & Indicators  
Each Channel Green/Red LED,
Healthy/Fault
Input Manual/Auto
Red LED(manual)
Keypad Manual/Auto
Channel (A/B)
Ethernet RJ 45, Front Panel
RS232 DB9 (Rear panel)
   
Protocols(Ethernet)  
Telnet  
SNMP  
Web Browser  

Environmental & Physical  
Temperature: 0° to 55° C
Relative Humidity: 0 to 95%, non-condensing
Power Requirements  
AC Input (±15%) 90 - 264 VAC, <10W
DC Input (optional)  
Dimensions (HxWxD): 1U x 19” x 12”

1200-MC Series PDF DOCUMENT